Difference between revisions of "Pitfalls and troubleshooting"
(→Unresolved resonance probability table sampling) |
(→Unresolved resonance probability table sampling) |
||
Line 4: | Line 4: | ||
=== Unresolved resonance probability table sampling === | === Unresolved resonance probability table sampling === | ||
− | Unresolved resonance probability table sampling is not used | + | Unresolved resonance probability table sampling is not used by default. This method is needed to account for self-shielding effects in the unresolved resonance region. The effect is usually not significant in thermal systems, but can lead to noticeable discrepancies in fast-spectrum systems. |
Probability table sampling is switched on using the [[Input syntax manual#set ures|set ures]] option. | Probability table sampling is switched on using the [[Input syntax manual#set ures|set ures]] option. |
Revision as of 17:09, 18 November 2015
Things to check in case of suspicious results
Unresolved resonance probability table sampling
Unresolved resonance probability table sampling is not used by default. This method is needed to account for self-shielding effects in the unresolved resonance region. The effect is usually not significant in thermal systems, but can lead to noticeable discrepancies in fast-spectrum systems.
Probability table sampling is switched on using the set ures option.